BioRetention

The BioRetention subassembly inserts links to create a bioretention area with three layers and an optional underdrain. The subassembly is based on requirements of the County of Los Angeles Low Impact Development Standards Manual, dated February 2014.

You should verify that the dimensions used match your interpretation of the referenced document.

Attachment

The attachment point is at the middle top of the bioretention.

Input Parameters

Note: All dimensions are in meters or feet unless otherwise noted. All slopes are in run-over-rise form (for example, 4 : 1) unless indicated as a percent slope with a “%” sign.

Parameter

Description

Type

Default

Biofiltration Width Biofiltration width Numeric, positive

5 ft

1.5 m

Mulch Thickness Thickness of mulch Numeric, positive

0.33 ft

0.10 m

Planting Mix Thickness Planting mix thickness under mulch Numeric, positive

2.0 ft

0.6 m

Gravel Thickness Gravel thickness under planting mix Numeric, positive

0.5 ft

0.15 m

Include Underdrain Include underdrain to remove water Yes/ No Yes
Underdrain Diameter Underdrain diameter Numeric, positive

0.5 ft

0.15 m

Underdrain Cover Underdrain cover Numeric, positive

0.5 ft

0.15 m

Underdrain Bedding Bedding under the underdrain pipe Numeric, positive

0.5 ft

0.15 m

Underdrain Trench Width Underdrain trench width Numeric, positive

2.5 ft

0.75 m

Target Parameters

This section lists the parameters in this subassembly that can be mapped to one or more target objects. For more information, see To Specify Corridor Targets.

Parameter

Description

Status

Underdrain Invert Profile May be used to override the fixed invert elevation of the underdrain pipe. The following object types can be used as targets for specifying the elevation: profiles, 3D polylines, feature lines, or survey figures. Optional

Runtime Logical Assignments

None.

Output Parameters

None.

Behavior

The initial point is set at the attachment point. The subassembly builds a mulch layer followed by a planting mix layer, followed by a gravel layer. If set to include an underdrain pipe the subassembly builds an underdrain pipe and pipe bedding.

Layout Mode Operation

In layout mode, this subassembly draws the bioretention using the input parameters.

Point, Link, and Shape Codes

The following table lists the point, link, and shape codes for this subassembly that have codes assigned to them. Point, link, or shape codes for this subassembly that do not have codes assigned are not included in this table.

Point, Link, or Shape

Code

Description

P1,P3 BioretentionTop Top of bioretention
P2 BioretentionCenter Center of bioretention
P4,P5 Mulch Bottom point of Mulch layer
P6,P7 Plant_Mix Bottom point of Plant Mix layer
P8, P9 Gravel Bottom point of Gravel
P10-P13 Underdrain Points around underdrain
P14 Invert Invert of underdrain pipe
L1-L2 Bioretention,Top Bioretention top layer
L4 Mulch Bottom of mulch layer
L8 Plant_Mix Bottom of Plant Mix layer
L11 Gravel,Datum Bottom of Gravel layer
L14 Underdrain,Datum Bottom of underdrain layer
S1 Mulch Mulch area
S2 Planting_Mix Planting Mix area
S3 Gravel Gravel area
S4 UnderdrainPipe Underdrain pipe layer