SideDitch

The subassembly is used to create a ditch structure with optional backslope and foreslopes.

Attachment

The attachment point is the innermost point on the grading links preceding the ditch structure. If grading links are omitted, then the attachment point is the innermost point on the inside wall of the ditch structure (shown in blue circle).

Input Parameters

Note: All dimensions are in meters or feet unless otherwise noted. All slopes are in run-over-rise form (for example, 4 : 1), unless indicated as a percent slope with a “%” sign.

Parameter Description Type Default
Side

Specifes to insert the subassembly either on the right or the left side of the attachment point.

Left / Right Right
Depth Inside depth of the ditch. Numeric, Positive

0.45 m

1.5 ft

Bottom Width Width of bottom of the channel. Numeric, Positive

0.5 m

1.5 ft

Sideslope Ditch sideslopes Numeric 1:2
Ditch Wall Depth Depth of the ditch wall. This is measured perpendicular to the side of the slope, as shown in the previous diagram. Numeric, Positive

0.1 m

0.33 ft

Inside Extension Height Non-lined extension of ditch inside over the attachment point Numeric, Positive

0.15 m

0.45 ft

Inside Backslope Width Ditch backfill width on the inside Numeric, Positive

1.5 m

5.0 ft

Outside Backslope Width Width of non-lined width beyond the outer point of the ditch structure Numeric, Positive

0.1 m

0.33 ft

Target Parameters

This section lists the parameters in this subassembly that can be mapped to one or more target objects, such as a surface, alignment, or profile object in a drawing. For more information, see To Specify Corridor Targets.

Target Parameters: None.

Output Parameters

None.

Behavior

The subassembly builds the shape for a ditch structure, as shown in the above illustration.

Note:

In Civil 3D 2010 and previous versions, the Ditch Wall Depth parameter was measured vertically. In Civil 3D 2011 and later, this parameter is measured perpendicular to the side of the slope. Therefore, if you open a drawing containing these subassemblies that was created in Civil 3D 2010 or prior in Civil 3D 2011 or later, and then rebuild the corridor(s), this parameter will be changed to reflect the new behavior. Any volume reports that use this subassembly will be updated to reflect the new behavior.

Layout Mode Operation

In layout mode, this subassembly is created outward, starting from the attachment point, as defined using the input parameters.

Point, Link, and Shape Codes

The following table lists the point, link, and shape codes for this subassembly that have codes assigned to them. Point, link, or shape codes for this subassembly that do not have codes assigned are not included in this table.

Point/Link Codes Description
P1, P6 Ditch_Back  
P2, P5 Ditch_Face  
P10 Ditch_In  
P11 Ditch_Out  
L9, L10, L11 Top, Datum  
L1 to L5 Top, Ditch_Top  
L6, L7, L8 Datum, Ditch_Bottom  
S1 Ditch Ditch structure shape area