The BasicBench subassembly inserts links to create cut or fill catch slopes with repeating benches as needed. You can define a swale width and depth at the benches. The last daylight slope to the target surface may be different than the bench slope.
The attachment point is at the inside edge of the initial cut or fill slope. This component can be attached to either the left or right side.
Parameter |
Description |
Type |
Default |
---|---|---|---|
Side |
Specifies which side to place the subassembly |
Left / Right |
Right |
Max Daylight Height |
The maximum allowable height for the cut and fill daylight link without benching. |
Numeric |
15.0 ft 4.5 m |
Bench Height |
The maximum allowable height for a bench before a new bench. |
Numeric |
10.0 ft 3.0 m |
Bench Slope |
The slope between benches. |
Numeric, positive |
1 (: 1) |
Bench Grade In |
The +/- % slope of the bench. Positive slopes are upward in the direction of increasing offset. |
Numeric |
4 (%) |
Bench Width In |
The width of the bench to the bench flowline. |
Numeric, positive |
4 ft 1.2 m |
Bench Grade Out |
The +/- % slope of the bench. Positive slopes are upward in the direction of increasing offset. |
Numeric |
4 (%) |
Bench Width Out |
The width of the bench from the bench flowline. |
Numeric |
4 ft 1.2 m |
Daylight Slope |
The daylight slope. |
Numeric, positive |
2 (: 1) |
This section lists the parameters in this subassembly that can be mapped to one or more target objects. For more information, see To Specify Corridor Targets.
Parameter |
Description |
Status |
---|---|---|
Daylight Surface |
Name of the daylighting surface. The following object types can be used as targets for specifying the surface: surfaces. | Required |
None.
None.
The initial hinge point is set at the attachment point. The hinge point elevation is checked against the target surface to determine if the section is in the cut or fill condition. An intercept is calculated to the target surface using the given Daylight Slope. If the height to the intercept exceeds the Max Daylight Height, the link with the Bench Height is inserted, and the bench is added. The hinge point is reset to the outside edge of the bench and the process is repeated until a daylight link is found that does not exceed the Max Daylight Height.
This subassembly contains a loop definition comprised of L2, L3, and L4 that is repeated until it reaches the surface target or until it is repeated a maximum of 10 times.
In layout mode, this subassembly draws the initial fill slope to 5 units.
The following table lists the point, link, and shape codes for this subassembly that have codes assigned to them. Point, link, or shape codes for this subassembly that do not have codes assigned are not included in this table.
Point, Link, or Shape |
Code |
Description |
---|---|---|
P1 - P5 | Top | |
P5 | Daylight | Daylight point, and daylight point for either the cut or fill condition. This only applies to the actual daylight point. |
L1 - L4 | Top |