VegetatedFilterStrip

The VegetatedFilterStrip subassembly inserts links to create a vegetated filter strip to treat storm water.

Attachment

The attachment point is at the inside edge of the Vegetated Filter Strip. This component can be attached to either the left or right side.

Input Parameters

Note: All dimensions are in meters or feet unless otherwise noted. All slopes are in run-over-rise form (for example, 4 : 1) unless indicated as a percent slope with a “%” sign.

Parameter

Description

Type

Default

Side Specifies which side to place the subassembly Left / Right Right
Include French Drain Outlet Include French drain outlet at end of filter Yes / No Yes
Berm Slope Slope of berm Numeric, positive 1 ( : 1)
Berm Width Width of berm Numeric, positive

2 ft

0.60 m

Berm Height Height of berm Numeric, positive

0.5 ft

0.15 m

Include Berm at Toe Include berm at toe to contain water Yes / No Yes
Planting Soil Depth Planting soil depth Numeric, positive

1.5 ft

0.45 m

Include Planting Soil Include planting soil Yes / No Yes
VFS Grade Vegetated filter strip grade Numeric -10%
VFS Width Vegetated filter strip width Numeric, positive

15 ft

4.5 m

French Drain Pipe Diameter French drain pipe diameter Numeric, positive

0.5 ft

0.15 m

French Drain Depth French drain depth Numeric, positive

1 ft

0.3 m

French Drain Width French drain width Numeric, positive

1 ft

0.3 m

Target Parameters

This section lists the parameters in this subassembly that can be mapped to one or more target objects. For more information, see To Specify Corridor Targets.

Parameter

Description

Status

VFS Width May be used to override the vegetated filter strip offset value and tie the edge to an offset alignment. The following object types can be used as targets for specifying the width: alignments, polylines, feature lines, or survey figures. Optional
VFS Elevation May be used to override the vegetated filter strip and tie the elevation to the elevation of a profile. The following object types can be used as targets for specifying the elevation: profiles, 3D polylines, feature lines, or survey figures. Optional

Runtime Logical Assignments

None.

Output Parameters

None.

Behavior

Starting at the attachment point, a finish grade surface and parallel subgrade are inserted using the given width and depth. Vertical links close the shape at either end of the vegetated filter strip. An optional berm is built at the far end of the vegetated filter strip. An optional French drain is constructed at the end of the vegetated filter strip.

Layout Mode Operation

In layout mode, this subassembly displays all links using the input parameters.

Point, Link, and Shape Codes

The following table lists the point, link, and shape codes for this subassembly that have codes assigned to them. Point, link, or shape codes for this subassembly that do not have codes assigned are not included in this table.

Point, Link, or Shape

Code

Description

P2 Filter_Outside Outside edge of vegetated filter strip
P5-P7 Berm
P11 Pipe_Invert Invert of the French drain pipe
L1 Filter, Top Top of vegetated filter strip
L2, L7 Datum
L5 Top, FrenchDrain Top of French drain
L9 Pipe
L10-12 Berm
S1 VFS Vegetated filter strip
S2 Berm
S3 FrenchDrain French drain

Coding Diagram