The ClarkCountyRainGardenV subassembly inserts links to create a Clark County Rain Garden V, adjacent to the curb.
You should verify the dimensions used match your interpretation of the standard plan.
The attachment point is at the inside edge of the inside slope. This component can be attached to either the left or right side.
Parameter |
Description |
Type |
Default |
---|---|---|---|
Side | Specifies which side to place the subassembly | Left / Right | Right |
Overall Width | Overall width of rain garden | Numeric, positive |
12.0 ft 3.6 m |
Depth From Gutter | Depth from the adjacent attach point. | Numeric |
-1.0 ft 0.3 m |
Soil Depth | Depth of soil | Numeric, positive |
2 ft 0.6 m |
Curb Offset | Offset from the attachment point | Numeric |
-0.5 ft 0.15 m |
Inside Sideslope | Inside sideslope | Slope | -4 ( : 1) |
Outside Sideslope | Outside sideslope | Slope | -4 ( : 1) |
This section lists the parameters in this subassembly that can be mapped to one or more target objects. For more information, see To Specify Corridor Targets.
None.
None.
None.
The initial point is set at the attachment point. The rain garden in then adjusted the entered offset distance. The depth of the rain garden is set from the input values.
In layout mode, this subassembly draws the rain garden in accordance with the input parameters.
The following table lists the point, link, and shape codes for this subassembly that have codes assigned to them. Point, link, or shape codes for this subassembly that do not have codes assigned are not included in this table.
Point, Link, or Shape |
Code |
Description |
---|---|---|
P1 | RG_Gutter | Rain garden insertion point |
P2 | RG_Top_In | Rain garden top inside |
P3 | RG_Top_Out | Rain garden top outside |
P6 | RG_Btm_Out | Rain garden bottom outside |
P7 | RG_Btm_In | Rain garden bottom inside |
L1-L3 | Top, RG_Slope | Top of rain garden slope |
L5-L7 | Datum | Datum |
L6 | Datum, RG_Btm | Rain garden bottom |
S1 | RainGarden | Rain garden |