RetainWallTapered

This subassembly inserts a retaining wall structure with one tapered side and an optional key at the bottom.

Attachment

The attachment point varies depending on whether the retaining wall is in cut condition or fill. If it is in fill, the attachment point is near the top of the retaining wall. If it is inserted in cut condition, the attachment point is near the footing.

Input Parameters

Note: All dimensions are in meters or feet unless otherwise noted. All slopes are in run-over-rise form (for example, 4 : 1), unless indicated as a percent slope with a “%” sign.

Parameter Description Type Default
Side

Specifes to insert the subassembly either on the right or the left side of the attachment point.

Left / Right Right
Wall Top Width Specifies the width of the wall at the top Numeric

0.958 ft

0.292 m

Top Height The distance between the top-of-the wall and the hook in fill or the new hook in cut. Numeric

1.320 ft

0.40 m

Footing Cover The depth of cover from the top-of-footing to the finish grade line on the back side of the wall in fill or to the hook when in cut. Numeric

1.667 ft

0.50 m

Key Species to add an optional key below the footing Boolean Yes

Wall height is determined from the top of the footing to the insertion point of the ground elevation on the vertical face, whichever is higher. Wall battered slope, width of the footing, offset of wall vertical face, optional key dimensions, and the location of the key center, are all functions of the wall height.

Target Parameters

This section lists the parameters in this subassembly that can be mapped to one or more target objects, such as a surface, alignment, or profile object in a drawing. For more information, see To Specify Corridor Targets.

Parameter Description Status
Wall Height May be used to override the fixed wall height and tie to a profile. The following object types can be used as targets for specifying this elevation: profiles, 3D polylines, feature lines, or survey figures. Optional
Target Surface Existing ground surface name to determine retaining wall in cut or fill. The following object types can be used as targets for specifying this surfaces: surfaces. Required

Output Parameters

None.

Behavior

This subassembly can be inserted on either the left or the right sides. The attachment point is different for the fill or cut condition. In fill, the attachment point is assumed to be where the finish grade intersects the inside face of the wall, at a distance of Top Height below the top of the wall. In cut, the attachment point is assumed to be where the finish grade intersects the inside face, at a distance of Footing Cover above the top-of-footing. The wall height is determined from the Wall Height or Profile input.

In fill, the sloping wall face is toward the center of the roadway. In cut, the sloping wall face is away from the roadway. If the Key option is set to No, then the base of the footing is a single horizontal link. If the Key option is used, links to define the optional Key are inserted.

Layout Mode Operation

In layout mode, the subassembly draws the retaining wall shape as specified by the input parameter values, assuming that the subassembly is in a fill condition.

Point, Link, and Shape Codes

The following table lists the point, link, and shape codes for this subassembly that have codes assigned to them. Point, link, or shape codes for this subassembly that do not have codes assigned are not included in this table.

Point/Link Codes Description
P1 RW_Front  
P2 RW_Top  
P3 RW_Back  
P14 RW_Hinge  
P12 RW_Inside Could be used as breaklines in building datum surface
P5 RW_Outside Could be used as breaklines in building datum surface
L1, L2, L3 Top, Wall  
L4,L5,L6 Footing_Bottom L4 = P6 to P7; L5 = P8 to P9; L6 = 10 to 11;
S1 RWall  

Coding Diagram