Bolted Connection Generator dialog box - Design Tab

All hole parameters (sizes, start/end plane, and so on) are specified in the Design tab.

Note: To insert a bolted connection the using Bolted Connection Generator, your assembly must contain at least one component. (It is necessary to place the bolted connection).

Also, you must be connected to the Content Center where the fasteners for bolted connection are stored. If you are not connected to the Content Center, the area on the right side where you select the fasteners is grayed out.

Access
Ribbon: Design tab Fasten panel Bolted Connection

Type

Select the type of Bolted Connection. Types of holes to select from:

Note: When you select the Blind connection option, Termination is defined as the start plane of the blind hole (the opposite side of the last part than the Through All selection).
Note: Insert countersunk screws into countersunk holes.

Placement

Defines the placement of the bolted connection.

First, select start and termination planes. This sequence defines several bolted connection parameters:

Options to specify the bolted connection position:

Linear
You specify the bolted connection placement by selecting the two linear edges.
Concentric
You specify the bolted connection placement by selecting a circular edge.
On Point
You specify the bolted connection placement by selecting a work point (mainly for non-hole features).
By Hole
You specify the bolted connection placement by selecting a hole (it locks bolted connection position, direction, and maximal diameter).
Based on the selected placement, the appropriate buttons for placement are enabled and you are prompted to specify the placement for the hole.
Start Plane
Select a bolted connection start plane. Start plane also defines the direction of bolted connection.
Linear Edge 1
Select the first linear edge referenced for dimensioning the placement of the hole.
Linear Edge 2
Select the second linear edge for hole placement.
Circular Edge
Selected circular edge defines the circle, hole is drilled to the center of the circle.
Point (s)
Bolted connection is inserted into the selected work point. Recommended when you want to place the bolt to a non-circular hole.
Existing Hole
Bolted Connection point is calculated according to the center of the selected hole. At the same time, the maximum possible bolt diameter is restricted by the hole.
Follow Pattern
Available only when the By Hole placement option is selected and a hole in the pattern within the graphics window is selected. You can insert into an existing pattern.
Termination
Select an end face of the bolted connection. Start plane and Termination restrict the area where the necessary number of holes is calculated.

Thread

Specifies all thread parameters. Selects the thread type and the diameter of a thread. Threads are read from the Threads.xls spreadsheet.

Right side area

Displays the bolted connection components. Select “Click to add a fastener” to add components to the bolted connection.

Note: Specify the placement of bolted connection first. Bolted Connection Generator filters the fasteners selection based on placement specifications made on the left side of the Desig tab. When the placement specifications are not done, selection of fasteners on the right side of the Design tab is not enabled.

When selection bolted connection fasteners you can narrow the selection. You can display fasteners according to Standard and Category.

Make sure that you have installed the appropriate libraries to Content Center. For example, you want to insert an ISO washer and you select the ISO Standard from the list but no fasteners are displayed you might have not loaded ISO library.

Also, a selected standard or category may not contain a fastener for particular selection.

Following fastener categories are available:
  • Bolts
  • Hex Head Bolts
  • Hex Head - Flanged Bolts
  • Socket Head Bolts
  • Round Head Bolts
  • Square Head Bolts
  • Countersunk Bolts
  • Washers
  • Nuts
  • Sheet Metal Nuts
Note: Not all categories are displayed for all fasteners. For example, to insert bolted connection into already created hole using the By hole option, Bolted Connection Generator automatically offers you to select from countersunk bolts only.

Select the row with a fastener. Three options are available to edit the fastener:

For all fasteners: Displays the Table dialog box where you can select from other fastener, if available.

For bolts: Hold the Alt key to open the Modify length/hole dialog box where you can change bolt length

For holes: Displays the Modify length/hole dialog box where you can change hole parameters (type, designation, parameter, and so on).

Deletes the component.
Displays a dialog box where you can select from filtered Content Center items. You can filter the selection by specifying the standard or category. Based on your selection only the fasteners that meet the criteria are displayed.
Note: Make sure that you have the library installed in Content Center.

Templates Library

Displays the list of bolted connection templates.

To display the Templates Library, on the Design tab, click More in the lower right corner.

Each new bolted connection can be created from a template. When you open the Bolted Connection Generator, click Set to apply the template to the currently designed bolted connection.

Now, templates library remembers recently used template.

Set
Applies selected template to a current content of the bolted connection.
Add
Adds a newly designed bolted connection to the template library.
Note: Add command is available when the complete geometry of bolted connection is specified, including start plane, reference, and an end plane.
Delete
Deletes the selected bolted connection template.

Tips:

Summary of Messages

Displays the reports about calculation. To open the Summary of Messages area at the bottom of the Calculation and Design tabs, double-click the double line at the bottom of tabs or click the chevron at the bottom of the tabs. The Message area incorporates a summary for all calculations (state and fatigue).

Graphical Preview

A graphic preview represents the selected geometry and bolted connection components. The preview is a schematic representation of a fastener. The preview includes the visibility of counterbore/countersunk hole geometry and differentiates between socket head bolts and hex head bolts.

Preview displays in the graphics window when you select first fastener in the Design tab.

Use the 3D grips within the preview to edit bolt length. Drag the 3D grip to an appropriate length. Only lengths available for selected bolts are available. A tooltip is displayed showing the fastener dimension. Double-click the 3D grip to display the Modify dialog box where you can select the dimension from list of available dimension for particular fastener.

Toolbar commands