Adds, modifies, and removes properties on selected loom occurrences. Also lists all segments that share a single loom occurrence.
Access: |
With an active harness assembly, right-click a loom occurrence, and then select Harness Properties. |
Name |
The unique name for the loom occurrence within the assembly. It is also the name used in the browser. |
Loom ID |
Sets the unique identifier for the loom occurrence within the assembly. Click the arrow to select from the list. The Loom ID enables proper tracking for a single loom that is attached to multiple segments. Only segments can share a loom. All looms with the same ID are counted as one object in the BOM, which provides a cumulative length of all loom segments. |
Order |
Displays the order in which the loom is placed when multiple looms are attached to a single harness object. Loom order is set when the loom is created or when modifying wire or segment properties. A loom order of 1, means the loom is the first loom placed on the harness object. The order of the loom also determines the size of the loom to attach. |
Length displays the various length values for a loom.
Length |
Displays the actual length of the loom occurrence. |
Adjusted Length |
Displays the sum of the lengths from all loom occurrences that make up a particular loom. |
Order list |
Lists all loom portions along with loom order, the segments to which they are assigned, and the length of the portion. |
Name |
Displays the library name of the selected loom. |
Category |
Displays the category in which the loom is organized, if applicable. |
Part Number |
Displays the part number for the selected loom. |
Thickness |
Displays the wall thickness for the selected loom that is added to the segment, wire, cable, or cable wire to which it is attached. The diameter of the segment or wire increases by 2 times the wall thickness of each loom that is attached. |
Range or Fixed |
Displays whether a range of values or a fixed value is allowed for the gauge or size of wires inserted into the loom. |
Min Diameter |
When set to Range, displays the smallest gauge allowed for the wires inserted into the selected loom. |
Max Diameter |
Displays the largest gauge allowed for the wires inserted into the selected loom. When set to Fixed only maximum gauge is allowed. |
Name |
Displays the entered property name. Click in the input area to enter a new property, or if available, click the arrow to select from the list. |
Type |
Data type for the selected property. Click the arrow to select an appropriate data type from the list. |
Value |
Enter a value for the selected property, if desired. |
Add |
Adds a new property to the list. |
Delete |