Contact pressure
Minimum hub length
Recommended values: L = (0.6 - 3) d
Force carried by one bolt
Strength check
p ≤ p A
where:
F a |
axial force [lb] |
|
T |
torque [lb ft] |
|
d |
shaft diameter [in] |
|
p |
contact pressure in a joint [psi] |
|
p A |
allowable pressure [psi] |
|
L |
hub length [in] |
|
υ |
clamping factor υ = 0.008 to 0.1 [-] |
|
k s |
slip safety [-] |
|
F |
force carried by one bolt [lb] |
|
F s |
force carried by all bolts [lb] |
|
i |
total number of bolts [-] |