Joint Pin Generator dialog box - Calculation tab

Extends the Design tab. Calculates generator data based on selections in the Design tab.

Access:

Ribbon: Design tab Fasten panel Joint Pin and click the Calculation tab.
Note: The Calculate command is available only if a pin is selected.

Type of Strength Calculation

Specifies the calculation method. It determines which parameters you enter, and which parameters are to be calculated.

Note: The selection list is enabled only when a pin is selected.

Pin Design

Designs optimum joint pin dimensions for the indicated load, dimensions and joint properties.

Check Calculation

Performs a strength check for the specified load, dimensions, and joint properties.

Loads

Loading is entered through power, speed or torque according to the selected method in the pull-down menu.

Power, Torque Speed

Calculates the speed according to the power and torque.

Torque, Speed Power

Calculates the power according to the torque and speed.

Power, Speed Torque

Calculates the torque according to the power and speed.

Dimensions

Pin Diameter

Choose a diameter of the pin.

Pin Length

Specifies the length of the pin.

Shaft Diameter

Enters the diameter of the shaft. Based on this dimension the appropriate pin is selected. You can enter the diameter or measure the diameter in Autodesk Inventor using the options displayed when you click the arrow next to edit field.

Hub Diameter

Specifies the diameter of the hub according to the part dimensions. If the hub diameter is smaller than the shaft diameter, the diameters turn red. This also indicates that the strength check of the pin is not satisfactory. You can enter the diameter or measure the diameter in Autodesk Inventor using the options displayed when you click the arrow next to edit field.

Note: The values in the edit field that are not satisfactory turn red when you click Calculate.

Joint Properties

Service Factor

Represents a Type of Loading and type of Mounting. The allowed material value is lowered according to the selected type. Click next to edit field to open the Service Factor dialog box where you can select the service factor value.

Desired Safety

With regards to accuracy and credibility of input information, importance of the coupling, quality of production and accuracy of the calculation, it is chosen in a range from 1.5 to 10.

Pin Material

 

Warning: Determines empirically the strength parameters of material and reflects minimum values applicable for a group of materials. Although these values are close to the values obtained using measurement of particular materials, it is recommended in cases of final calculations to use parameters of the material according to the material sheet or specifications of the producer

Material

Specifies material values you enter, or selects a material from the Material Database.

If a material is selected from the Material Database, its values are inserted automatically into the following 3 edit fields, and the edit fields are locked. To unlock the field, clear the box.

Allowable Shear Stress

Specifies allowable pin shear stress used in calculation. The joint is checked for shear during the strength check.

Shaft Material

Material

Specifies material values you enter, or selects a material from the Material Database.

If a material is selected from the Material Database, its values are inserted automatically into the following 3 edit fields, and the edit fields are locked. To unlock the field, clear the box.

Allowable Pressure

Specifies the allowable pressure of the shaft material with the least quality in the Joint Properties group. The shaft is checked for pressure during the strength check.

Hub Material

Material

Specifies material values you enter, or selects a material from the Material Database.

If a material is selected from Material Database, its values are inserted automatically into the following 3 edit fields, and the edit fields are locked. To unlock the field clear the check box.

Allowable Pressure

Specifies the allowable pressure of the hub material with the least quality in the Joint Properties group. The hub is checked for pressure during the strength check.

Results

To display the Results area on the right side of the Calculation tab, double-click the double line on the right or click the chevron.

The area displays the calculated values and the joint pin strength check. Values are calculated when you click Calculate.

The units of the results values can be changed. Double-click the specified value you want to change.

Summary of Messages

Displays the reports about calculation. To open the Summary of Messages area at the bottom of the Calculation and Design tabs, double-click the double line at the bottom of tabs or click the chevron.

Design tab

Service Factor

Menu Commands