T2048
|
WARNING: T2048
|
WILL ATTEMPT TO CORRECT INTERPOLATION ELEMENT
id DEFINITION
|
|
Cause:
|
The specified
RBE3 element is not valid and the
AUTOFIXRIGIDELEM model parameter was set to ON. The Model Translator will attempt to correct the element definition by adding rotational components to the element dependent degrees of freedom.
|
|
Action:
|
If this message was followed by a
T2043 error, check the element definition. Otherwise, the element was corrected automatically.
|
|
Remarks:
|
See Autodesk Nastran Reference Guide, Section 4,
Bulk Data, for entry format.
|