| E5118 | FATAL ERROR: E5118 | EXCESSIVE VECTOR RESULTANT MISMATCH DETECTED IN SUBCASE ID1 |
| Cause: | The vector resultant error measure was greater than 1.0E-3. In static solutions the load and single point constraint vector resultants should be equal and opposite. An error measure greater than 1.0E-3 indicates a possible loss of accuracy due to numerical ill-conditioning. | |
| Action: | Check the maximum displacement magnitude for the analysis. If this value is excessive, check your model for a lack of constraint. See messages E5001,E5002,and E5051. If you are using either the PCGLSS or VIS iterative solver, set the SPARSEITERTOL model parameter to a smaller value (default 1.0E-5). See message E5085. | |
| Remarks: | None. |