T2089
|
FATAL ERROR: T2089
|
TABLE ID REQUIRED IN FIELD
field FOR NONLINEAR MATERIAL TYPE
|
|
Cause:
|
An optional table identification field was blank when required. This can be caused by one of the following:
- A
MATS1 Bulk Data entry was specified as a nonlinear elastic material (type equal to NLELAST in field 4) with no table specified in field 3.
- A
MATVE Bulk Data entry was specified with no table specified in field 3 and/or field 4 and with no corresponding
MAT1 entry to supply default values for moduli.
|
|
Action:
|
Perform the following actions:
- For the MATS1 entry add the required table identification number in field 3.
- For the MATVE entry either reference a table identification number of an existing
TABVE Bulk Data entry or add a MAT1 entry with material property data specified in fields 3, 4, and 5.
|
|
Remarks:
|
See Autodesk Nastran Reference Guide, Section 4,