T2083
|
FATAL ERROR: T2083
|
TABLE IN FIELD
field NOT COMPATIBLE WITH NONLINEAR MATERIAL TYPE
|
|
Cause:
|
An incompatible table type was specified. This can be caused by one of the following:
- A
MATS1 Bulk Data entry referenced an incompatible table in field 3. When the material nonlinearity type on the MATS1 entry is set to NLELAST,
TABLES1 and
TABLEST types may be specified. When the material nonlinearity type is set to PLASTIC, only the TABLES1 type may be specified.
- A
MATVE Bulk Data entry referenced an incompatible table in field 3 and/or field 4. Only the
TABVE type may be used.
|
|
Action:
|
Perform the following actions:
- For the MATS1 entry change either the material nonlinearity type or reference to a compatible table type.
- For the MATVE entry change the reference to a TABVE table type.
|
|
Remarks:
|
See Autodesk Nastran Reference Guide, Section 4,
Bulk Data, for entry format.
|