T2145

T2145 FATAL ERROR: T2145 INITIAL CONDITIONS AT GRID id COMPONENT n NOT PERMITTED
Cause: A transient initial condition was specified using a TIC Bulk Data entry at the same degree of freedom where direct enforced motion was also specified.
Action: Remove the conflicting degree of freedom on the TIC Bulk Data entry.
Remarks: See Autodesk Nastran Reference Guide, Section 4, Bulk Data, for entry format.