T2145 | FATAL ERROR: T2145 | INITIAL CONDITIONS AT GRID id COMPONENT n NOT PERMITTED |
Cause: | A transient initial condition was specified using a TIC Bulk Data entry at the same degree of freedom where direct enforced motion was also specified. | |
Action: | Remove the conflicting degree of freedom on the TIC Bulk Data entry. | |
Remarks: | See Autodesk Nastran Reference Guide, Section 4, Bulk Data, for entry format. |