T2136

T2136 WARNING: T2136 UNABLE TO GENERATE SURFACE CONTACT USING SPECIFIED PARAMETERS
Cause: Automated surface contact generation was requested using either a CONTACTGENERATE Case Control command or CONTACTGEN model parameter and was unable to generate any contact using the specified parameters.
Action: Adjust the maximum normal activation distance using the maxad field on the CONTACTGENERATE command or using the CONTACTGEN parameter.
Remarks: See the Case Control section for command format and the Parameters section for more information.