T2283
|
FATAL ERROR: T2283
|
ELEMENT
id REFERENCES A NON-COMPATIBLE MATERIAL
id
|
|
Cause:
|
The specified element identification number referenced a non-compatible material type. This error occurs when a model containing shell elements references a material also referenced on a
PSOLID Bulk Data entry through a
PCOMP entry referenced in field 5 of the PSOLID. The PCOMP entry referenced on the PSOLID contained 2d orthotropic materials which were converted to 3d orthotropic materials for compatibility.
|
|
Action:
|
Either remove the PSOLID Bulk Data entry or its reference to the PCOMP entry in field 5 if not used, or add a new PCOMP entry which references
MAT8 materials with different identification numbers not linked to shell elements via PCOMP and use this in field 5 of the PSOLID entry.
|
|
Remarks:
|