T2284

T2284 WARNING: T2284 COMPOSITE PLY MATERIAL DEFINED IN FIELD field IS INCOMPLETE
Cause: The orthotropic material referenced in the specified MATL8 Bulk Data entry field is missing data required for MCT ply failure analysis.
Action: Check that the MAT8 Bulk Data entry referenced has E1, E2, NU12, G12, G13, and G23 specified.
Remarks: See Autodesk Nastran Reference Guide, Section 4, Bulk Data, for entry format.