T2033
|
FATAL ERROR: T2033
|
PLOAD ENTRY SPECIFIED AN INVALID LOAD LOCATION
|
|
Cause:
|
The pressure load location specified on a
PLOAD1,
PLOAD4, or
PLOADX1 entry was invalid due to one of the following:
- The PLOAD1 load location was defined as fractional and specified less than 0.0 or greater than 1.0.
- The PLOAD1 load location was defined as an actual distance, and when internally converted to a fractional distance, was less than 0.0 or greater than 1.0.
- The PLOAD4 grid points defining the loaded face of a solid element were invalid.
- The PLOADX1 grid points defining the loaded edge of an axisymmetric element were invalid.
|
|
Action:
|
Perform the following actions:
- For the PLOAD1 entry, check the SCALE field for the correct option. The fractional options (FR and FRPR) require the Xi values in fields six and eight to be in the range (
). The distance options (LE and LEPR) require the Xi values to be less than or equal to the element length (LE option) or projected element length (LEPR option).
- For the PLOAD4 and PLOADX1 entries, check the grid points used to define the loaded face or edge respectively. Duplicate grid points are not permitted.
|
|
Remarks:
|
See Autodesk Nastran Reference Guide, Section 4,
Bulk Data, for entry format.
|