G3052

G3052 WARNING: G3052 CHECK NORMAL FOR CONTACT ELEMENT id CONTACT SEGMENT id
Cause: For slide line elements:
  • A grid point referenced on a secondary slide line was initially positioned well below the primary line contact boundary.
  • This usually indicates that the y-axis of the slide line primary segment is pointing away from one or more secondary grid points.
For contact surface elements:
  • A grid point referenced on a secondary contact surface was initially positioned well below the primary surface contact boundary.
  • This usually indicates that the z-axis of the surface contact primary segment is pointing away from one or more secondary grid points. The nodal ordering of the primary slide line defines the element y-axis, which must point toward the secondary region.
Action: For slide line elements:
  • Check that the slide line plane vector specified on the BCONP entry is oriented correctly.
  • Try changing the penetration type on the BCONP entry to unsymmetrical.
  • Check the ordering of the primary slide line grid points and regenerate if necessary.
For contact surface elements:
  • Try changing the penetration type on the BSCONP entry to unsymmetrical.
  • Check the ordering of the primary contact surface grid points and regenerate if necessary. The nodal ordering of the primary contact surface defines the element z-axis, which must point toward the secondary region.
Remarks: See Autodesk Nastran Reference Guide, Section 4, Bulk Data, for entry format and additional remarks.