Description: Select the type of solution.
Format:
SOLUTION = type
Example:
SOLUTION = LINEAR STATIC
Alternate Format and Example:
SOLUTION = 101
Option | Definition | Type |
---|---|---|
type | Type of solution sequence. Available solution types depend on the license purchased. This directive may also be specified in the Model Initialization File (see Section 2, Initialization, for more information on SOLUTION). | Character |
Remarks:
Solution Character Variable | Solution Number |
---|---|
LINEAR STATIC or STEADY STATE HEAT TRANSFER | 101 |
MODAL | 103 |
LINEAR BUCKLING | 105 |
NONLINEAR STATIC | 106 |
DIRECT FREQUENCY RESPONSE | 108 |
DIRECT TRANSIENT RESPONSE | 109 |
MODAL COMPLEX EIGENVALUE | 110 |
MODAL FREQUENCY RESPONSE | 111 |
MODAL TRANSIENT RESPONSE | 112 |
NONLINEAR TRANSIENT RESPONSE | 129 |
NONLINEAR STEADY STATE HEAT TRANSFER | 153 |
NONLINEAR TRANSIENT HEAT TRANSFER | 159 |
NONLINEAR BUCKLING | 180 |
PRESTRESS STATIC | 181 |
LINEAR PRESTRESS MODAL | 182 |
LINEAR PRESTRESS FREQUENCY RESPONSE | 183 |
LINEAR PRESTRESS TRANSIENT RESPONSE | 184 |
NONLINEAR PRESTRESS MODAL | 185 |
NONLINEAR PRESTRESS FREQUENCY RESPONSE | 186 |
NONLINEAR PRESTRESS TRANSIENT RESPONSE | 187 |
LINEAR PRESTRESS COMPLEX EIGENVALUE | 188 |
NONLINEAR PRESTRESS COMPLEX EIGENVALUE | 189 |