CMASS4

Scalar Mass Property and Connection to Scalar Points Only

Description: Defines a scalar mass element that is connected only to scalar points and without reference to a property entry.

Format:

Example:

Field Definition Type Default
EID Element identification number. Integer > 0 Required
M Mass value. Real Required
S1, S2 Scalar point identification numbers of connection points. Integer > 0 See Remark 2

Remarks:

  1. Element identification numbers must be unique with respect to all other element identification numbers.
  2. S1 or S2 may be blank indicating a constrained coordinate.
  3. A scalar point specified on this entry need not be defined on an SPOINT entry.