DYNRSLTMETHOD

Description: Dynamic results calculation method. Two methods are available for the calculation of element results during modal transient and frequency response: MATRIX and DISP. Both methods will give the same results. Typically, when a large number of time/frequency steps are specified versus the number of modes requested, MATRIX works best. AUTO selects the most efficient method based on the number of modes requested and the number of time/frequency steps specified.

Option/Type:

MATRIX
DISP
AUTO

Default: AUTO