TOPTGEN

Description Type Default

Automated Topology Optimization Generation (ATOG). A value between 0 and 8 defines one of the predefined topology design optimization solutions generated. There are eight options:

0 - Automated topology optimization generation is disabled.

1 - The objective is minimize compliance, the design constraint is volume fraction (mass fraction), and the solution is linear statics.

2 - The objective is minimize volume fraction (mass fraction), the design constraints are stress and compliance index, and the solution is linear statics.

3 - The objective is minimize volume fraction (mass fraction), the design constraint is maximum displacement and compliance index, and the solution is linear statics.

4 - The objective is minimize volume fraction (mass fraction), the design constraint is maximum singe point constraint force and compliance index, and the solution is linear statics.

5 - The objective is minimize volume fraction (mass fraction), the design constraint is compliance index, and the solution is linear statics.

6 - The objective is minimize volume fraction (mass fraction), the design constraint is modal frequency, and the solution is normal modes.

The character variables: DISABLE, COMPVF, VFSTRESS, VFDISP, VFSPCF, VFCOMP, AND VFFREQ may be used in place of the numerical options 0 through 6. All objectives are minimized and all constraints are upper limits except for modal frequency which is a lower frequency limit. Multiple subcases are supported and applicable to all constraints. See also TOPTMANCONSTR, TOPTDESIGNCONSTR, and TOPTCOMPINDEX.

0 ≤ Integer ≤ 6

DISABLE/

COMPVF/

VFSTRESS/

VFDISP/

VFSPCF/

VFCOMP/

VFFREQ