CELAS1

Scalar Spring Connection

Description: Defines a scalar spring element.

Format:

Example:

Field Definition Type Default
EID Element identification number. Integer > 0 Required
PID Property identification number of a PELAS entry. Integer > 0 Required
G1, G2 Grid point identification numbers of connection points. Integer > 0 See Remark 2
C1, C2 Component numbers. 0 ≤ Integer ≤ 6 See Remark 2

Remarks:

  1. Element identification numbers must be unique with respect to all other element identification numbers.
  2. A blank may be used to indicate a grounded terminal G1 or G2 with a corresponding blank or zero C1 or C2. A grounded terminal is a point whose displacement is constrained to zero.
  3. The two connection points (G1, C1) and (G2, C2), must be distinct.