Select Clash Test Options

There are four default clash test types for you to choose from:

To select the Clash Test Options:

  1. Click Home tab > Tools panel > Clash Detective .
  2. On the Select tab, select the test you want to run from the Type drop-down list. Any custom clash tests that have been defined (see Create Custom Clash Tests) appear at the end of the list.
  3. Enter the Tolerance required, which will be automatically converted to the Display Units. See Clash Detective Terminology for more information.
  4. If you want to run a time-based or soft clash test, select the appropriate option in the Link box. For example, selecting TimeLiner will make Clash Detective produce a clash report based on the Clash Detective settings, TimeLiner simulation settings, and the project data contained in TimeLiner. For more information and usage examples, see Time-Based and Soft Clash Testing.