P&ID Validation Settings Dialog Box

Controls the type of errors that are flagged.

 Ribbon: Home Validate tab Validate Config (for P&ID workspace)
 Shortcut menu: Project Manager Right-click the project node Validation Settings
 Command entry: validateconfig

Error Reporting

Controls the type of errors that are flagged by the validation program.

P&ID objects
Specifies which types of P&ID errors are flagged. The following options are available:
  • Size Mismatches. Identifies size discrepancies in components and lines.
  • Spec Mismatches. Identifies discrepancies in the specifications of components and lines.
  • Non-terminating Lines. Identifies lines that do not connect to components, or do not have a termination symbol.
  • Unconnected Components. Identifies components that are not connected to a line at all its attachment points. If a component has no attachments points, at least one line must be connected to it.
  • Flow Direction Conflicts. Identifies errors in the direction in which materials flow through lines.
  • Orphaned Annotations. Identifies annotations that have moved beyond the tolerance threshold of their associated components.
  • Unresolved Off-page Connectors. Identifies off-page connectors that do not continue on another drawing in the same project.
3D Piping
Specifies which types of Plant 3D errors are flagged.
Note: To see disconnection markers in the model, on the Home tab Visibility panel, click the Toggle Disconnect Markers icon .
The following options are available:
  • Disconnected port Identifies Plant 3D parts that are disconnected.
  • Placeholder parts. Identifies Plant 3D placeholder parts.
  • Property mismatches. Identifies Plant 3D property mismatches.
Base AutoCAD Objects
Specifies which types of AutoCAD errors are flagged. The following options are available:
  • All AutoCAD Objects. Identifies the presence of any type of AutoCAD object that could be misinterpreted as P&ID symbols.
  • Lines. Identifies AutoCAD lines that could be misinterpreted as P&ID schematic lines.
  • Polylines. Identifies AutoCAD polylines that could be misinterpreted as P&ID schematic lines.
  • Circles. Identifies AutoCAD circles that could be misinterpreted as instrument bubbles.
  • Annotations. Identifies AutoCAD text, multiline text (mtext), leaders, dimensions, attributes, and tables that could be misinterpreted as P&ID annotations.
  • Blocks. Identifies AutoCAD xrefs, blocks, and dynamic blocks that could be misinterpreted as P&ID components.
3D Model to P&ID checks
Specifies which types of mismatches between the 3D Model and the P&ID drawing are flagged. The following options are available:
  • Tagged inline items are in a 3D model but not in a P&ID drawing. Identifies Plant 3D objects that exist in the model but not in the P&ID drawing.
  • Tagged inline items are in a P&ID drawing but not in a 3D model. Identifies Plant 3D objects that exist in the P&ID drawing but not in the 3D model.
  • Items with the same tag are different types in 3D models and P&ID drawings. Identifies items that have identical tags but are different types.
  • Properties have different values in P&ID drawings and 3D models. Identifies items that have different property values. For example, a pipe is 6” in the P&ID drawing and 4” in the 3D model.
  • Inline items are on different lines in P&ID drawings and 3D models. Identifies where matching inline components are on different lines in the P&ID drawings and 3D models. For example, a gate valve is on l-100 in the P&ID drawing and on l-200 in the 3D model.
  • Equipment in a 3D model has more nozzles than it does in a P&ID drawing. Identifies extra nozzles in the 3D model that do not exist in the P&ID drawing.
  • Equipment in a 3D model has fewer nozzles than it does in a P&ID drawing. Identifies extra nozzles in the P&ID drawing that do not exist in the 3D model.

Description