RC walls are calculated according to the principles given in:
CALCULATION METHOD
The wall design is based on the assumption that the wall works in its plane as an RC section. Parabolic-linear distribution of compressive stresses in the section is adopted here.
Calculations are performed for an unreinforced wall and, if needed, for one with reinforcement. The design process is focused on the bottom section of the wall.
The calculation algorithm is as follows.
The basic dimensions of walls are presented in the following drawing.
It is assumed that:
a ≥ 10 cm are internal walls (and external, but according to EN all not reinforced walls should have ≥ 12 cm, and user can choose in calculation options whether it is internal or external wall
a ≥ 12 cm are external walls
Individual steps of the calculation algorithm for walls subjected to non-seismic loads are as follows:
σ moy =N/(b · hw) ≤ σ ulim
σ band,moy =N/(b · hw) ≤ σ ulim
If mean compressing stress in the wall or mean stress on compression strap exceeds the allowable stress in concrete, calculations are interrupted. Dimensions of the wall section should be increased.
Φ = min(1-2 · etot/hw; 1.14(1-2 · etot/hw) - 0.02 · l0/hw )
Where etot=e0+ei
Nulim= b · hw · fcd,pl · Φ
σ ulim = Nulim/(b · hw)
If Numax ≥ Nulim then reinforcement for compression with bending will be arranged near wall edges
The minimum ratio of the vertical reinforcement must equal:
As,vmin = 0,002 · Ac
The maximum ratio of the vertical reinforcement must equal:
As,vmax = 0,04 · Ac
The distance between two adjacent bars should not exceed 3 · hw and 400mm
The horizontal reinforcement fulfills the conditions:
(the reinforcement is distributed uniformly along the wall height)
As,hmin = max (25%Av; 0,001 · Ac)
The distance between two adjacent bars should not exceed 400mm
As indicated in the assumptions of the method, calculations of this reinforcement are focused on ensuring that bending with compression can be carried by a structure; it is generated in a 'hidden zone' of the width equal to d'.
σ cp = N/(hw · b)
t cp = k · V/(hw · b)
σ c,lim = fcd - 2 · (fctd · (fctd+fcd)) ½
If σ cp ≤ σ c,lim :
fcvd= (fctd,pl 2 + σ cp · fctd,pl 2 ) ½
If σ cp > σ c,lim :
fcvd= (fctd,pl 2+ σ cp·fctd,pl2 - 0,25 · ( σ cp - σ c,lim )2) ½
If τ cp <= fcvd then shear reinforcement calculated on the basis of following criterions must be distributed uniformly along the wall length :
vmin = 0.35/ γ c · fck ½
k = min(1+(200/b) ½ ); 2)
CRd,c =0.18/ γ c
σ cp =min(0,2 · fcd; N/(hw · b))
VRd,c = max((CRd,c · k · (100 · ρl · fck) (1/3)+k1 · σcp )*hw*d; (vmin+ k1 · σcp ) · hw · d) (1/3))
Vertical ULS loads must meet the following criterion:
V<=VRd,c
Anti-shrinkage reinforcement:
= vertical
= horizontal