Panel Thickness

Returns thickness information for a selected panel.

RSA_PANEL_THICKNESS (Information type, Panel no.)

The RSA_PANEL_THICKNESS formula syntax has the following arguments:

Information type

The following types of information are available:

Homogeneous data
  • THICKNESS

    Calculated thickness of the panel

  • NAME

    Name of thickness label

  • TYPE

    Thickness type of the panel

    The following results for the argument are available:

    • HOMOGENEOUS_CONSTANT

      Constant.

      Accessible parameters: THH_TH_CONST

    • HOMOGENEOUS_VARIABLE_ALONG_LINE

      Variable along a line.

      Accessible parameters: THH_TH, THH_TH1

    • HOMOGENEOUS_VARIABLE_ON_PLANE

      Variable on a plane.

      Accessible parameters: THH_TH, THH_TH1, THH_TH2

    • ORTHOTROPIC_BIDIR_BOX_FLOOR

      Bidirectional box floor.

      Accessible parameters: THO_H, THO_H1, THO_H2, THO_A, THO_A1, THO_B, THO_B1, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_DOUBLE_SIDED_UNIDIR_RIBS

      Double-sided, unidirectional ribs.

      Accessible parameters: THO_H, THO_A, THO_HA, THO_A1, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_GRILLAGE

      Grillage.

      Accessible parameters: THO_H, THO_A, THO_B, THO_B1, THO_A1, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_HOLLOW_CORE_SLAB

      Hollow slab.

      Accessible parameters: THO_H, THO_A, THO_H0, THO_HC, THO_A1, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_MATERIAL

      Material orthotropy.

      Accessible parameters: THO_H, THO_N1, THO_N2, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_ONE_SIDED_BIDIR_RIBS

      One-sided, bidirectional ribs.

      Accessible parameters: THO_H, THO_A, THO_HA, THO_HB, THO_A1, THO_B, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_ONE_SIDED_UNIDIR_RIBS

      One-sided, unidirectional ribs.

      Accessible parameters: THO_H, THO_A, THO_HA, THO_A1, THO_B, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_SLAB_ON_TRAPEZOID_PLATE

      Slab on a trapezoid plate.

      Accessible parameters: THO_H, THO_A, THO_A2, THO_H1, THO_A1, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_UNIDIR_BOX_FLOOR

      Unidirectional box floor.

      Accessible parameters: THO_H, THO_H2, THO_A, THO_H1, THO_A1, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_USER

      User defined.

      Accessible parameters: THO_MATRIX, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_TRAPEZOID_PLATE

      Trapezoid plate.

      Accessible parameters: THO_H, THO_A, THO_A1, THO_A2, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_CORRUGATED_PLATE

      Corrugated plate.

      Accessible parameters: THO_H, THO_A, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_SLAB_COMPOSED_WITH_TRAPEZOID_PLATE

      Slab composed with a trapezoid plate.

      Accessible parameters: THO_H, THO_A, THO_A2, THO_H1, THO_A1, THO_TH1, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

    • ORTHOTROPIC_CONSTANT_THICKNESS_WITH_REDUCED_STIFFNESS

      Constant thickness with reduced stiffness.

      Accessible parameters: THO_H, THO_TH, THO_TH1, THO_TH2, THO_VECTOR, THO_DIR_TYPE, THO_DIRY

Homogeneous data

  • THH_TH_CONST

    Thickness constant

  • THH_TH

    Thickness

  • THH_TH1

    Thickness 1

  • THH_TH2

    Thickness 2

  • THH_POINT1

    Point 1

  • THH_POINT2

    Point 2

  • THH_POINT3

    Point 3

  • THH_REDUCTION

    Reduction

Orthotropic data
  • THO_A

    A

  • THO_A1

    A1

  • THO_A2

    A2

  • THO_B

    B

  • THO_B1

    B1

  • THO_DIR_TYPE

    Direction (X, Y, Z, VECTOR)

  • THO_DIRY

    Disregarded bending direction (0 - false, 1 - true)

  • THO_H

    H

  • THO_H0

    H0

  • THO_H1

    H1

  • THO_H2

    H2

  • THO_HA

    HA

  • THO_HB

    HB

  • THO_HC

    HC

  • THO_MATRIX

    Matrix

  • THO_N1

    N1

  • THO_N2

    N2

  • THO_TH

    Thickness

  • THO_TH1

    Thickness 1

  • THO_TH2

    Thickness 2

  • THO_VECTOR

    Vector

Note: If you type an argument in the formula manually, enclose the text in quotation marks. You can also select or type a cell address (for example A1) which the data will be loaded from.

Panel no.

The following input methods are available:

  • Number - Type an integer.
  • Cell address - select or type a cell address (for example A1) which the data will be loaded from.
  • Graphical selection - select this option in the dialog or type "@".
Note: If panels are selected graphically in Autodesk Robot Structural Analysis Professional, then the program returns information for the first panel selected.