Room Assignment Type by Project Standard Reference

Understand the room assignment types available when working with different project standards.

The project standard defines all room names and corresponding area assignments with the room assignment type family. The information in the room assignment type is reported to rooms specified with the same type. Imagine a hospital project with hundreds of identical rooms. Room assignment types allow you to define the area assignment for a room name once and with a click, you have correctly defined the area assignment for all rooms.

By default, Areabook contains a comprehensive list of predefined area assignments which are loaded in each project. You can edit and change the assignments or add new room names and assignments.

You can find the room assignment type families in the Revit installation directory for families, in the folder Areabook_Library:

Room assignments by International Standard are defining the room name. For example:
International Standard family file names DIN-Standard family file names

English: RoomAssignmentType.rfa

French: RoomAssignmentType_DIN-INT.rfa

German: Flaechenzuordnung_INT-DEU.rfa

Portuguese: RoomAssignmentType_INT-PTB.rfa

Russian: RoomAssignmentType_INT-RUS.rfa

English: RoomAssignmentType_DIN277-2016_ENU.rfa

French: RoomAssignmentType_DIN277-2016-FRA.rfa

German: Flaechenzuordnung DIN277-2016.rfa.

Portuguese: RoomAssignmentType_DIN277-2016-PTB.rfa

Russian: RoomAssignmentType_DIN277-2016-RUS.rfa

Room assignments by International Standard are defining the room name. For example:
Room Name Room Type Calculation Factor %

Comments

Living Living/Sleeping 100
Hall Sideroom 100
Office --- 100
Terrace Sideroom 50
My Room Not defined 100
Room assignments by the DIN Standard are defining the room name according to DIN 277. For example (in German):
Room Name Room Type Calculation Factor % Room Enclosure Sector Area Type DIN 277-1 NRA Subdivision DIN 277-1
Living Living/Sleeping 100 Regular case (R) NUF 1-Wohnen und Aufenthalt
Hall Sideroom 100 Regular case (R) VF 9-Verkehrserschl./sicherung
Office --- 100 Regular case (R) NUF 2-Büroarbeit
Terrace Sideroom 50 Regular case (R) NUF 1-Wohnen und Aufenthalt
My Room not defined 100 Special case (S) not defined not defined

The global assignment can be changed later when editing the rooms.

Note: When room names have no equivalence in the room assignment family, those rooms get their type assigned as not defined.