Change Buildingbook calculation settings to allow for wall, floor, and ceiling openings.
The VOB Standard specifies many rules for calculating quantities. Rules differ depending on the trade for which the quantities are calculated, especially in regard to the subtraction of sub-areas, such as openings in walls or floors/ceilings/foundation slabs.
The Calculation Settings dialog opens
Name | Description |
---|---|
VOB - Wall Openings - by square measure | |
Ignore | Ignores opening subelements when calculating building part quantities when calculated by square measure. Either Yes or No. If Yes, the following range is considered. |
Area - equal to or less than |
The default value for this option is 2.5². Wall openings smaller than 2.5 m² are ignored when the walls are calculated by square measure. Openings larger than 2.5 m² are calculated. |
VOB - Wall Openings - by solid measure | |
Ignore | Ignores opening subelements when calculating building part quantities when calculated by solid measure. Either Yes or No. If Yes, the following range is considered. |
Volume - equal to or less than |
The default value for this option is 0.5². Wall openings smaller than 0.5 m² are ignored when the walls are calculated by solid measure. Openings larger than 0.5 m² are calculated. |
VOB - Floor, Ceiling, Foundation Slab Openings - by square measure | |
Ignore | Ignores opening subelements when calculating building part quantities when calculated by square measure. Either Yes or No. If Yes, the following range is considered. |
Area - equal to or less than |
The default value for this option is 0.1². Wall openings smaller than 0.1 m² are ignored when the walls are calculated by square measure. Openings larger than 0.1 m² are calculated. |
VOB - Floor, Ceiling, Foundation Slab Openings - by solid measure | |
Ignore | Ignores opening subelements when calculating building part quantities when calculated by solid measure. Either Yes or No. If Yes, the following range is considered. |
Volume - equal to or less than |
The default value for this option is 0.5². Wall openings smaller than 0.5 m² are ignored when the walls are calculated by solid measure. Openings larger than 0.5 m² are calculated. |