Plumbing fixtures are often hosted components, placed on a vertical face, face, or work plane. 
- In the Project Browser, open a view where you want to place a plumbing fixture. 
 
- In the Project Browser, right-click the view, click Apply Template Properties to Current View, and select Plumbing Plan from the Apply View Template dialog. 
Note: The Plumbing Plan view template is available when you create a project using the mechanical default template. 
  
- Click Systems tab
Plumbing & Piping panel
, and select a particular fixture type from the Type Selector. 
  
- On the ribbon, verify that Tag on Placement is selected to tag the plumbing fixture automatically. 
 
- On the Options Bar, to include a tag leader, select Leader and specify the length. 
 
- Click Place Plumbing Fixture tab
Placement panel
, 
, or 
 to specify a host component. Tip: When placing a plumbing fixture on a work plane, it may be necessary to Pick a Plane in the Work plane dialog, or by selecting Placement Plane on the Options Bar when placing the fixture. 
  
- Move the cursor to where you want to place the plumbing fixture, and click. 
Tip: You can press Space to rotate the plumbing fixture prior to placing it in the view. The fixture is rotated by 90 degrees each time you press Space.