Modify wall part parameters to change the default connection parts for generating structural wall assemblies.
Name | Description |
---|---|
Lifters | |
Type | Specifies the lifting anchor and type for the precast wall. |
Minimum Distance to Edge | Specifies the minimum distance from the lifter to either edge of the wall. |
Minimum Top Distance to Opening | Specifies the minimum distance from the top of a lifter to any opening in the wall. |
Tension Capacity | Specifies the rated tensile strength of the lifting anchor. |
Side Lifters if Height Exceeds | Specifies the minimum wall height required before placing side anchors in the precast wall. |
Bracing Inserts | |
Type | Specifies the bracing and type for the wall connection. |
Distance Bracing Inserts and | Specifies the location of wall bracings as a distance from the upper edge or lower edge of the wall. |
As Percentage of Wall Height | Select to use a percentage of the total precast wall height instead of specific units for the Distance Bracing Inserts parameter. |
Position Bracing Inserts | Specifies where bracing inserts are placed. Select either None, On View Side, Opposite to View Side, or Both Sides. |
Minimum Distance to Opening | Specifies the minimum distance from the bracing to any opening in the wall. |
Connections | |
Profile Frontal Wall Connection | Specifies the profile applied on the front/end of precast walls. |
Profile Side Wall Connection | Specifies the profile applied on the sides of precast walls. |
Profile T-Connection | Specifies the profile applied on the front/end of precast walls adjacent in a T-connection. |
Horizontal Profile | Specifies the edge profile and type where precast walls are split horizontally. Either Horizontal Profile or Vertical Profile. |
Nooses | Specifies the loop and type connection for precast walls. |
Cast in Plate | Specifies the anchor plate and type for precast wall mounting. |