Modify type properties to change the structure and thickness of a ceiling, its fill pattern, and more.
To change type properties, select an element and click Modify tabProperties panel (Type Properties). Changes to type properties apply to all instances in the project.
Name | Description |
---|---|
Construction | |
Structure | Opens a dialog in which you can add, change, and delete layers comprising a compound structure. See Compound Structure. |
Thickness | Specifies the total thickness of the ceiling. (Read-only) |
Graphics | |
Coarse Scale Fill Pattern | Specifies the fill pattern for this type of element when displayed at a coarse detail level. See View Properties. |
Coarse Scale Fill Color | Applies a color to the fill pattern for this type of element in a coarse-scale view. |
Identity Data | |
Keynote | Adds or edits the keynote for this type of element. Click in the value box to open the Keynotes dialog. See Keynotes. |
Model | Specifies the model for the materials comprising the ceiling. |
Manufacturer | The manufacturer for the ceiling materials. |
Type Comments | General comments about the ceiling type. This information can be included in a schedule. |
URL | Sets a link to a web page. |
Description | Provides a description of this family type. |
Assembly description | Description of the assembly based on the assembly code selection. |
Assembly code | Uniformat assembly code selected from hierarchical list. |
Type Mark | A value to designate the particular ceiling, such as 1A, 2B, and so on. This value must be unique for each ceiling in a project. Revit LT warns you if the number is already used but allows you to continue using it. |
Cost | Cost of the materials for constructing the ceiling. |