Understand errors in units and numerical constants in formulas that are used to calculate dimensions.
Formulas can operate on the following types of data:
When using formulas to calculate dimensions, an error in units typically results when you do not follow the rules required by an operation.
Examples
Revit LT is working with the base physical dimension (Time, Length, Mass, Temperature, and so on). Dimensional analysis is independent of the unit used to represent or measure the base physical dimension (seconds, meters, kg, degrees Celsius, and so on).
Another source of dimensional errors is the interpretation of numerical constants in formulas.
When a formula includes a parameter name or a numerical constant with explicit units (such as 5 kg), Revit LT knows the units of the expression with certainty. However, the software also allows you to enter a number without a unit (such as 5). In this case, Revit LT guesses the units of the number to make the units in the formula agree. This issue is the reason for the common trick of adding *1 or /1 to a formula.
The best practice is to specify units for each constant in the formula.
Examples
The following units can be used in formulas for constants. This list is not exhaustive, but it includes the most common unit types.
Unit | Symbols |
---|---|
Linear feet | ' or LF |
Inches | " |
Square feet | SF or ft2 or ft^2 |
Cubic feet | CF or ft3 or ft^3 |
Seconds (time) | s |
Hours | h |
Pounds mass | lbm |
Pounds force | lbf |
Kips | kip |
Radians | rad |
Fahrenheit degrees | °F |
Decimal degrees | ° |
Kips per square inch | ksi or kip/in2 |
Pounds per square inch | psi or lbf/in2 or psig or psia |
Unit | Symbols |
---|---|
Millimeters | mm |
Centimeters | cm |
Decimeters | dm |
Meters | m |
Kilograms | kg |
Celsius degrees | °C |
Kelvin | K |
Newtons | N |
Kilonewtons | kN |
Meganewtons | MN |
Pascals | Pa |
Megapascals | MPa |