Member Definition - Additional Parameters (NF EN1995-1:2005/NA:2010/A2:2014)

Use this dialog to define the parameters of a timber member type according to the NF EN1995-1:2005/NA:2010/A2:2014 code.

Access

Dialog elements



Load parameters
Select the Load type for the member.
Section parameters
Enter the Anet/Agross ratio. This value is used to consider section factors exposed to tensile force.
Additional conditions for round sections
Use this option to perform calculations on members that have a round section bent biaxially.
Select Unidirectional bending to use the vector sum of the moments My and Mz as a resultant moment, in order to treat the member as unidirectionally bent.
Solid wet timber
Consider dimensions reduction 3.2.(1)P
Considers the dimension reduction due to the wood humidity during the assembly.
Select this option, and then enter the percentage corresponding to the humidity of the wood during the installation.
Humidity during installation near its fibre saturation point (kdef+1) - 3.2.(4)
Select this option to increase all coefficients kdef (as defined in table 3.2) by 1.
Influence of cracks during shear
Select if you want the influence of cracks during shear (as defined in chapter 6.1.7.(2) of the code) to be calculated automatically or manually. By default, the automatic option is selected. To specify the kcr coefficient, select User and enter a value.