Seismic Analysis Parameters (Canadian Code NBC 2010 - Static)

Parameters of the seismic simplified analysis according to the equivalent lateral force method depend on a seismic code and a method of defining values of the fundamental periods selected in the Seismic Analysis dialog.

The following structure types may be defined in each direction independently:

Approximate method

The fundamental period (Ta) depends on the structure type, and on its effective height (hn). It is calculated according to the point 4.1.8.11.3. as follows:

Ta = Ct * (hn) x

User-defined method

No restrictions apply on user-defined values.

Precise method

When the Precise Method is used, the fundamental period (Ta) depends on the structure type and on the results obtained with the Approximate Method. It is calculated according to the point 4.1.8.11.3.(d).

Code parameters

The code parameters for a seismic analysis according to NBC 2010 are defined as follows:

In all cases, if the following condition (4.1.8.7.1.(a)) is not fulfilled, the lateral earthquake force will be equal to zero:

IEFaSa(0.2) < 0.35.

Base shear force (V)

Base shear force (V) is calculated according to the formula:

V = S(Ta) * Mv * Ie * W/(Rd * Ro)

Where:

Fa and Fv are available in tables 4.1.8.4 B and C.