Use this dialog box to view and edit survey observations.
Specifies the point number.
When creating a new point and automatic point numbering is off, you must specify the point number. If automatic point numbering is on, then the points are automatically numbered.
Specifies an optional name for the point.
Specifies the measured horizontal angle. It is assumed to be clockwise (right). Use a negative number (-) to turn counter-clockwise (left). Expressed in the current units.
Specifies the angle type to locate the point. Either angle, deflection angle, face 1, face 2, or quadrant bearing.
Specifies the distance from the instrument point to the point being located. It is measured in the current units.
Specifies the distance type to locate the point. Specify slope, horizontal, or None.
Specifies the vertical angle or distance depending on the Vertical Type.
Specifies the method of measuring the vertical. Either Vertical Angle or Vertical Distance.
Specifies the vertical distance between the ground level and the focal point of the prism or stadia.
Specifies the scale factor that affects how ground measurements are translated into grid measurements. The horizontal distances are then multiplied by this factor when the Scale Factor correction is checked in the Measurement Corrections property in the Survey Database Settings dialog.
Displays the calculated northing for the point.
Displays the calculated easting for the point.
Displays the calculated level for the point.