To Enter an Level for a Transparent Command

  1. Run a transparent command until you are prompted to enter a level.
  2. Do one of the following:
    • To accept the default level that is displayed on the command line, press Enter.
    • Enter g. The level is calculated using the entered gradient and a previously entered point.
    • Enter s. The level is calculated using the entered slope and a previously entered point.
    • Enter y. The level is taken from the X, Y location on the current surface.
    • Enter t. If there is more than one surface in the drawing, you are prompted to select the surface from which the level is read.
    Note: During a running command, the default prompts for level change, depending on how the previous level was entered. Enter e to reset the prompts back to the defaults described above.