Cable Insert/Edit Data Fields to Display Dialog Box
Specifies which fields to include, the field order, and the field labels.
Find
Command entry:
AEMULTICABLE
Click Change Format on the Cable Insert/Edit dialog box.
List of Options
The following options are displayed.
Available Fields
Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
Fields to Report
Specifies the fields to display in the report, and the field order.
Remove
Removes the selected field from the Fields to Report list.
Remove All
Removes all the fields from the Fields to Report list.
Move Up
Moves the selected field up one spot in the Fields to Report list.
Move Down
Moves the selected field down one spot in the Fields to Report list.
Available Fields
Each line item in the list can include two connected components, referred to as the From and To components. Whether a component is considered the From or the To component is based on the wire sequence for the wire network. The wire sequence can be defined specifically or can default to the Tag/Wire Number/Wire Sequence Order defined on the Drawing Format tab of the Drawing Properties dialog box. The From field labels end in a "1" and the To field labels end in a "2".
WIRENO
Wire number
LOC1
Location value on the From component
CMP1
Tag value on the From component
PIN1
Terminal number on the wire connection attribute of the From component
LOC2
Location value on the To component
CMP2
Tag value on the To component
PIN2
Terminal number on the wire connection attribute of the To component
WLAY1
Layer of the wire connected to the From component
WLAY2
Layer of the wire connected to the To component
REF1
Line reference, X-Y Grid, or X Zone location of the From component
REF2
Line reference, X-Y Grid, or X Zone location of the To component
SH1
Sheet value (%S) for the drawing where the From component is located
SH2
Sheet value (%S) for the drawing where the To component is located
CBL
Cable tag
CBLWC
Cable wire or cable core color
CBLLOC
Cable location value
CBLMFG
Cable manufacturer value
CBLCAT
Cable catalog part number
CBLASMB
Cable ASSYCODE assignment
DESC1CBL-DESC3CBL
Cable description values 1 - 3
CBLP1C2
Cable parent or child (parent = 1, child = 2)
CMP:PIN1
Combined tag and terminal number of the wire connection attribute on the From component
CMP:PIN2
Combined tag and terminal number of the wire connection attribute on the To component
SEC1
Section value for the drawing where the From component is located
SUB1
Sub-section value for the drawing where the From component is located
SEC2
Section value for the drawing where the To component is located
SUB2
Sub-section value for the drawing where the To component is located
INST1
Installation value on the From component
INST2
Installation value on the To component
IECCMP1
IEC tag value on the From component
IECCMP2
IEC tag value on the To component
PD1
TERMDESC value on the wire connection of the From component
PD2
TERMDESC value on the wire connection of the To component
SEQ1
Wire connection sequence value of the From component
SEQ2
Wire connection sequence value of the To component
PNLWDLEV1
Panel equivalent level (WDLEV) value of the From component
PNLWDLEV2
Panel equivalent level (WDLEV) value of the To component
CMPHDL1
Entity handle value of the From component block
CMPHDL2
Entity handle value of the To component block
DWGIX1
DWGIX value, as listed in FILETIME table of project database, for the drawing where the From component is located
DWGIX2
DWGIX value, as listed in FILETIME table of project database, for the drawing where the To component is located
DWGNAM1
Drawing value (%D) for the drawing where the From component is located
DWGNAM2
Drawing value (%D) for the drawing where the To component is located
CBLHDL
Handle value for the cable marker block
CBLINST
Cable installation value
CBLDWGIX
DWGIX value, as listed in FILETIME table of project database, for the drawing where the cable marker is located
WIREHDL1
Entity handle for the wire connected to the From component
WIREHDL2
Entity handle for the wire connected to the To component
XDIR1
Wire connection direction code and suffix for the From component
XDIR2
Wire connection direction code and suffix for the To component
PNLX1
Wire connection's physical X-coordinate value for the From component
PNLY1
Wire connection's physical Y-coordinate value for the From component
PNLZ1
Wire connection's physical Z-coordinate value for the From component
PNLXDIR1
Panel wire connection direction for the From component
PNLX2
Wire connection's physical X-coordinate value for the To component
PNLY2
Wire connection's physical Y-coordinate value for the To component
PNLZ2
Wire connection's physical Z-coordinate value for the To component
PNLXDIR2
Panel wire connection direction for the To component
CLEN
Panel layout calculated wire length to run between the From and To components
WIRECOLOR1
Color value for the wire type definition for the wire connected to the From component
WIRESIZE1
Size value for the wire type definition for the wire connected to the From component
USER1_1 to USER20_1
User1-User20 values defined for the layer of the wire connected to the From component
WIRENUM1
Wire numbering value for the wire type definition for the wire connected to the From component; 0=no wire numbering, 1=wire numbering
WIRECOLOR2
Color value for the wire type definition for the wire connected to the To component
WIRESIZE2
Size value for the wire type definition for the wire connected to the To component
USER1_2 to USER20_2
User1-User20 values defined for the layer of the wire connected to the To component
WIRENUM2
Wire numbering value for the wire type definition for the wire connected to the To component; 0=no wire numbering, 1=wire numbering