Wire Tagging (Project-Wide) Dialog Box

AutoCAD Electrical toolset processes wire line entities into wire networks, and inserts or updates wire numbers associated with them across a project.

Find
 Command entry:  AEWIRENO

Select Sequential and click Project-Wide.

Wire tag mode

Specifies to use the sequential or line-reference based setting for the drawing.

Sequential (1st tag defined for each drawing)

Starts at the wire number specified for that drawing (as set in the Drawing Properties > Wire Numbers dialog box). A starting wire number must be assigned for each drawing.

Sequential (consecutive drawing to drawing)

Allows you to type in a starting wire number and increments from there, ignoring the defined setting of the starting wire number.

Reference-based tags

Sets the wire number based on the line-reference value.

To do

Specifies to process all the wiring or just the untagged (new) wires.

Cross-reference Signals

Updates cross-reference text on wire signal source and destination symbols.

Freshen database (for Signals)

Updates the database for wire signal source and destination symbols.

Format override

Specifies the wire tag format to use for overriding the format set in the Drawing Properties dialog box.

Use wire layer format overrides

Overrides the default wire number format (set in the Layers section of the Drawing Properties Drawing Format dialog box) by using layer-defined formats.

Insert as fixed

Forces all wire numbers to be fixed (they do not update if wire number retagging is run again at a later date).