AutoCAD Electrical toolset processes wire line entities into wire networks, and inserts or updates wire numbers associated with them across a project.
FindSelect Sequential and click Project-Wide.
Wire tag mode |
Specifies to use the sequential or line-reference based setting for the drawing. |
|
Sequential (1st tag defined for each drawing) |
Starts at the wire number specified for that drawing (as set in the Drawing Properties > Wire Numbers dialog box). A starting wire number must be assigned for each drawing. |
|
Sequential (consecutive drawing to drawing) |
Allows you to type in a starting wire number and increments from there, ignoring the defined setting of the starting wire number. |
|
Reference-based tags |
Sets the wire number based on the line-reference value. |
|
To do |
Specifies to process all the wiring or just the untagged (new) wires. |
|
Cross-reference Signals |
Updates cross-reference text on wire signal source and destination symbols. |
|
Freshen database (for Signals) |
Updates the database for wire signal source and destination symbols. |
|
Format override |
Specifies the wire tag format to use for overriding the format set in the Drawing Properties dialog box. |
|
Use wire layer format overrides |
Overrides the default wire number format (set in the Layers section of the Drawing Properties Drawing Format dialog box) by using layer-defined formats. |
|
Insert as fixed |
Forces all wire numbers to be fixed (they do not update if wire number retagging is run again at a later date). |