Set Power Source/Load Value Dialog Box

This utility marks a component with a power source and load value. A related routine, when invoked, then scans the wire interconnections and reports if there is too much load on a given power source.

Find
 Command entry:  AEPOWERLOADLEVELS

Select the component for the power source or load value. The value is added to an AutoCAD Electrical toolset connection attribute. This dialog box contains a list of available connection points. If you select near the connection point for the power value it is preselected in the dialog box. Enter the power source and load value and an optional units value. These values are saved on the connection point as invisible xdata.

Note: As you add these power source or load values, think of AutoCAD Electrical toolset tracing through these components to see what the load is on the power source. Pick the terminal to which the value is added accordingly.

Source/load assignment

Source/Load

Indicates to set the source or load value.

Value

Specifies the source or load value to save on the connection point.

Units

(Optional) Specifies the units for the source or load value. Select from the drop-down list to specify the units.

Potential assignment

Optional for voltage level mismatch checks. Select from the drop-down list to specify the potential value.