Terminal Strip Table Settings Dialog Box

Defines the settings for the Terminal Strip table object.

Find
 Command entry:  AETSE

Make your selection on the Terminal Strip Selection dialog box and click Edit. Click the Layout Preview tab and select Tabular Terminal Strip (Table Object). Click Settings.

Find

 Command entry:  AETSEGENERATOR

Rows Per Section

Specifies how many rows for each table section. If the table break falls between rows within one terminal definition, the entire terminal definition is placed in the next table section. This results in a table section with fewer rows than defined.

Note: If the terminal definition is the first one in the section and exceeds the number of rows per section, the entire terminal definition is kept together in one section.

Sections Per Drawing

Specifies how many table sections to insert on each drawing. All sections are placed on new drawings unless the option “Insert All Sections on Active Drawing” is selected.

Note: The “Insert All Sections on Active Drawing” option is not available when using the Terminal Strip Table Generator tool.

Section Placement

Specifies where to place the table in the drawing. You can enter x and y values or pick a point on the screen.

Section Offset

Specifies the distance between sections, offset direction, and the base point for the distance measurement.

  • Distance: Specifies the distance between sections.
  • Direction: Specifies the direction for the offset.
  • Base Point: Specifies the base point for the distance measurement between sections.

Scale/Angle on Insert

Specifies the scale and angle of the table sections when inserted. These settings are reflected in the preview.

Drawing Information for Table Output

  • First Drawing Name: Specifies a starting drawing file location and file name to use for the automatic creation of the drawing files. The drawings are automatically added to the active project and display at the end of the drawing list in the Project Manager. The last character of the drawing file name is incremented for each drawing created.
  • Template: Specifies the template file to use for any new drawings. Enter a template file name or click Browse to search for and select a template file.

Show Unused Wire Connections in Table

Select to display all rows for each terminal even if there is no connected component. The Wires per Connection value for the terminal defines the number of rows.

Note: A terminal without any connected components has one row in the table.

Preview