Attach a destination signal to a wire segment of a wire network and relate it to the source signal arrow.
After the source signal arrow is attached to a wire in the drawing, you can attach a destination signal to a wire segment of a wire network. It enables the wire number assigned to another source wire network to carry over to the current network automatically.
Attach a destination signal
Select wire end for Destination:
Select the top of the hot wire on the schematic on the left side of the drawing at line reference 402 (2)
Code: 24 VDC
Signal Arrow Style: 1
Click OK + Update Source.
The cross-references for your signal insert into the drawing above the hot wire.
Attach source and destination signals to the neutral wires.
To return to AEGS03.dwg
Click Find .Select wire end for Source:
Select the bottom of the neutral wire at line reference 332 (3)
Code: 24 VDC NEUTRAL
Click OK.
To open AEGS04.dwg
Click Find .Select wire end for Destination:
Select the top of the neutral wire at line reference 402 (4)
Code: 24 VDC NEUTRAL
Signal Arrow Style: 1
Click OK + Update Source.
The cross-references for your signal insert into the drawing above the neutral wire.
Temporary graphics illustrate the flow of the signals on your drawings.