Attach a destination signal to a wire segment of a wire network and relate it to the source signal arrow.
After the source signal arrow is attached to a wire in the drawing, you can attach a destination signal to a wire segment of a wire network. It enables the wire number assigned to another source wire network to carry over to the current network automatically.
Attach a destination signal
Select wire end for Destination:
Select the top of the hot wire on the schematic on the left side of the drawing at line reference 402 (2)
Code: 24 VDC
Signal Arrow Style: 1
Click OK + Update Source.
The cross-references for your signal insert into the drawing above the hot wire.
Attach source and destination signals to the neutral wires.
To return to AEGS03.dwg
ClickSelect wire end for Source:
Select the bottom of the neutral wire at line reference 332 (3)
Code: 24 VDC NEUTRAL
Click OK.
To open AEGS04.dwg
ClickSelect wire end for Destination:
Select the top of the neutral wire at line reference 402 (4)
Code: 24 VDC NEUTRAL
Signal Arrow Style: 1
Click OK + Update Source.
The cross-references for your signal insert into the drawing above the neutral wire.