ReinforcedConcreteCribWall

The ReinforcedConcreteCribWall subassembly inserts links to create a Reinforced Concrete Crib Wall Based on Caltrans Standard Plan C7A.

You should verify that the dimensions used match your interpretation of the standard plan.

Case: Face of Wall

Case: Top of Wall

Attachment

The attachment point is at the inside edge of the initial cut or fill slope. This component can be attached to either the left or right side.

Input Parameters

Note: All dimensions are in meters or feet unless otherwise noted. All slopes are in run-over-rise form (for example, 4 : 1) unless indicated as a percent slope with a “%” sign.

Parameter

Description

Type

Default

Side Specifies which side to place the subassembly Left / Right Right
Batter of Wall Batter of wall Vertical / B 1:6 / B 1:4 B 1:6
Load Case Load case Flat / Embankment Flat
Wall Type Wall type Type A / Type B / Type C Type C
Attach Point Attach point Top of Wall / Face of Wall Face of Wall

Target Parameters

This section lists the parameters in this subassembly that can be mapped to one or more target objects. For more information, see To Specify Corridor Targets.

Parameter

Description

Status

Bottom of Wall May be used to set the bottom of wall elevation. The following object types can be used as targets for specifying the elevation: profiles, 3D polylines, feature lines, or survey figures. Optional
Face of Wall May be used to set the face of wall elevation point. The following object types can be used as targets for specifying the elevation: profiles, 3D polylines, feature lines, or survey figures. Optional (Attachment Point = Top of Wall)
Top of Wall May be used to set the top of wall elevation. The following object types can be used as targets for specifying the elevation: profiles, 3D polylines, feature lines, or survey figures. Optional (Attachment Point = Face of Wall)

Runtime Logical Assignments

The dimensions of the wall are set from the input parameters and the saved values of the Caltrans Standard Plan C7A.

Output Parameters

None.

Behavior

The initial hinge point is set at the attachment point. The dimensions of the walls are then set by the runtime logical assignments based on the input parameters. The shape is then built.

Layout Mode Operation

In layout mode, this subassembly draws reinforced concrete crib wall based on the input parameters.

Point, Link, and Shape Codes

The following table lists the point, link, and shape codes for this subassembly that have codes assigned to them. Point, link, or shape codes for this subassembly that do not have codes assigned are not included in this table.

Point, Link, or Shape

Code

Description

P1 WallFace Face of wall
P2-P9 Top
P10-P14 Bottom
L1, L9-L12 Top
L13-L16 Datum
S1-S4 Concrete

Coding Diagram