Use this tab to define the appearance of the pipe in a profile view.
Specifies the method that will be used to define and draw the dimensions of the pipe wall.
The inner and outer pipe wall dimensions are drawn according to the actual pipe dimensions.
The inner and outer pipe wall dimensions are drawn according to user-specified values. The following size options are available:
Specifies which components of the pipe shape display a hatch pattern.
The hatch pattern is displayed only in the central area of the pipe, and not in the pipe wall area of the pipe. When this option is selected, the pipe wall (which is the area between the inner wall and the outer wall of the pipe) is not hatched.
The hatch pattern is displayed in the entire area of the pipe, including the pipe wall area. When this option is selected, the pipe wall (which is the area between the inner wall and the outer wall of the pipe) is hatched.
The hatch pattern is displayed only in the pipe wall area. The pipe wall area is the area between the pipe inner wall and the pipe outer wall.
Specifies the method that will be used to define and draw the dimensions of the pipe ends.
The pipe end line draws to the inner walls of the pipe.
The pipe end line draws to the outer walls of the pipe.
The pipe end lines draw to a size specified by the user. The size options available are the same as the options available for the pipe wall dimensions.
Specifies which components of a pipe crossing display a hatch pattern.
The hatch pattern is displayed only to the inner walls of pipe crossings.
The hatch pattern is displayed all the way to the outer walls of pipe crossings.
The hatch pattern is displayed only within the pipe wall area of pipe crossings.
When this option is selected, the angle of the hatch lines for the pipe align with the angle of the pipe.
When this option is selected, the appearance of pipe to pipe connections in profile view is cleaned up. This option is available for multiple adjoining pipes that are connected to other pipes with null structures. This option must be selected for the clean up to occur, and the cleanup occurs only on the pipes that are connected to other pipes with null structures between them. For more information, see About Cleaning Up Pipe-to-Pipe Connections. You can also set this option on the Plan tab of the Pipe Style dialog box for pipe to pipe connections displayed in plan views. By default, this option is not checked.