Stop Condition Editor

When executing an analysis workflow, you can use the Stop Condition Editor to define stop conditions. For example Gas Network Analysis: Find Connected, Wastewater Network Analysis: Find Connected, or Water Network Analysis: Find Connected.

Note: The Stop Condition Editor list displays only the stop conditions that are not assigned to any tracing template.

To create a stop condition

  1. In the AutoCAD Map 3D toolset Maintenance workspace, open a project.
  2. In the Industry Explorer task pane, click the Workflow explorer icon.
  3. Right-click the workflow, for example, Find Connected With Stop Conditions.
  4. Click Execute.
  5. In the Stop Conditions section of the Workflows pane, click Add.
  6. In the Stop Condition Editor dialog box, click New and enter a name for the used stop condition.

    If you do not enter a name, the stop condition is used for the current process but is not stored for later use.

  7. Select a feature class.
  8. Select an attribute in that feature class.
  9. Enter a condition value for the attribute, such as =100.

    There is no blank space between the value and the operator.

    If the network trace finds a feature of the selected feature class with the specified attribute, the network trace stops at that feature.

  10. Click OK to save the stop condition.