Tutorial A5: Set Up the Model and Analysis Type
Start
Autodesk Inventor Nastran
.
From
Open
, navigate to the
C:\Users\Public\Public Documents\Autodesk\Inventor Nastran 2024\Tutorial\en-us\Inventor 2024
folder and open
RSA.ipt
.
In
Inventor Nastran
, click
File
,
Save As
and save the part with another name, such as
RSA_1.ipt
. This allows you to reuse the original part.
Click
Environments
>
Autodesk Inventor Nastran
.
In the
Part
tree, right-click
Analysis 1
>
Edit
. Set the Analysis
Type
to
Shock/Response Spectrum
.
On the
Output Controls
tab, select
Displacement
,
Velocity
,
Acceleration
, and
Stress
.
Note that the
Options
tab has a
Spectrum Data
section with options specific to this analysis type. Set these options as shown below:
On the
Tools
menu, click
Document Settings
>
Units
. Set the
Length
unit to
inch
, and the
Mass
unit to
lbmass
. These will now be the default units.
Note:
You can also set units for the analysis on the Part tree by right-clicking
Units
>
Edit
and selecting a Unit System that uses inch and lbmass.
Parent topic:
Tutorial A5: Shock/Response Spectrum Analysis of a Bracket