Energy simulation can sometimes fail for a variety of reasons.
To check the status of your simulations, go to gbs.autodesk.com, open the project, and check its run status and error messages.
The following are 3 of the most common reasons for a failed energy simulation.
To confirm the cause of the problem, in the Advanced Energy Settings dialog, under Material Thermal Properties, disable Detailed Elements. Then try the energy simulation again. For more information, see Use Detailed Elements for Material Thermal Properties.
To address the issue, reset the coordinates closer to the model: In Revit, click Manage tabProject Location panelCoordinates drop-down (Specify Coordinates at Point). Pick a point in the model at the ground plane level, somewhere in the center of the building. Set X = 0, Y = 0, and Z to the ground plane level.
To address the issue, set the perimeter Zone Depth to Zero in the Energy Settings dialog.
If these steps do not solve the problem or you experience other problems, contact insight.support@autodesk.com. If possible, include your model.