Cuts an element (such as a wall or pipe) at a selected point, or removes a segment between 2 points.
When you split a wall, the resulting parts are individual walls that can be worked on independently. When you split an MEP element, such as a pipe, the individual segments are no longer connected.
When you split a pipe, a fitting is added according to the settings in the routing preferences. Revit uses the contents of the Union field. If a Union is not defined, then Revit uses the contents of the Flange field. If both a Union and a Flange are defined, the contents of the Flange field are used. When you split a duct, Revit uses the contents of the Union field. When you split a cable tray or conduit, Revit uses the contents of the Union field in the Type Properties.
You can split a toposolid into two distinct elements and then edit them independently.
After splitting the element, change the toposolid type to depict roads, lakes, plazas, or hills.
You can also delete entire portions of the toposolid. For example, you can use the Split tool to remove unwanted portions of a toposolid generated by an imported file, when the imported file fills unsurveyed areas with unwanted artifacts.
To split a toposolid
Revit LT enters sketch mode.
Closed Loop | Open Loop |